The hidden cost of batch reactor cleaning, and why it belongs in your ROI case
When companies weigh up batch against flow, they look at yield, throughput and footprint. Cleaning rarely makes the list, yet it is one of the most wasteful parts of batch manufacturing. Our new calculator shows what a Coflore RTR could save on your process.

Batch cleaning is wasteful by design
Every batch reactor in fine chemical and API manufacturing has to be cleaned between batches or products, usually with solvent. Standard methods include solvent boil-out: part-fill the vessel, heat to reflux, hold, drain and repeat or alternatively using a spray ball to rinse the vessel out. Both methods are slow, energy-hungry and uses large volumes of solvent.
Published studies show the scale of the waste:
Large solvent volumes. A study of a pharmaceutical batch plant found each solvent fill averaged about a third of the reactor's volume, with around two fills per clean. Each clean produced 1 to 10 m³ or more of waste solvent per reactor. [1]
Repeated cleans. Stubborn residues can need 5 to 10 boil-outs. In one published case, the cleaning procedure used 9 to 11 methanol refluxes. [2]
More cleaning than needed. In the same plant study, reflux lasted 10 hours on average, but most of the residue came off in the first 1.5 hours. The authors concluded that vessels were often cleaned more intensely than necessary. [2]
Lost production time. Sources at a major pharmaceutical company have estimated that changeovers can take up about a third of available plant operating time. [3]
All of that solvent has to be bought, heated, then recovered or sent for disposal. And while the reactor is being cleaned, it is not making product.
Flow cleans a fraction of the volume, a fraction as often
The Coflore RTR has a working volume of just 100 L, but because it runs continuously its output is far larger than its size suggests. At a 10-minute residence time it processes 600 L per hour, or 14.4 m³ a day. That is comparable to a 3,000 imperial gallon (13.6 m³) batch reactor running one batch per day (see our batch comparison).
That changes the cleaning picture in two ways:
136 times less reactor volume to clean. You clean 100 L of reactor instead of 13.6 m³.
One clean per campaign, not one per batch. The RTR can run continuously for days, then be cleaned once by clean in place (CIP). A batch reactor making the same product is often cleaned after every batch, or every few batches.
The two effects multiply, so the longer the campaign, the wider the gap.

What the waste looks like in practice
Take a process with a 10-minute residence time, run for one week, with methanol as the cleaning solvent. The RTR runs continuously and gets one CIP clean of four reactor volumes. The equivalent 13.6 m³ batch reactor is cleaned after each of its seven batches, with two washes of 30% of its volume each time.
One-week campaign | Coflore RTR | Batch reactor |
Reactor volume | 100 L | 13.6 m³ |
Number of cleans | 1 | 7 |
Total cleaning solvent | 400 L | 57,281 L |
The batch reactor uses around 143 times more cleaning solvent. Over 99% of it could be avoided through switching to a continuous flow process in the Coflore RTR, saving more than 56,000 L. With our new cleaning solvent calculator, you are able to input the cost per volume of solvent (purchase & disposal) and then get an estimate of return on investment in a currency of your choosing. In the example above, if we assumed that this process was performed by an Indian chemical manufacturer and that the cleaning solvent used was methanol, with a total cost of INR 65,000 per tonne, then the weekly cost saving equates to around 29.5 lakhs (around £24k as of November 2026).
Repeat campaigns like this through the year and the numbers become hard to ignore. Over 50 weeks, this example adds up to around 2.8 million litres of solvent.
Cleaning: the overlooked line in your ROI case
Investment cases for flow chemistry usually focus on yield, selectivity, safety, footprint and throughput. Cleaning tends to be left out and treated as a fixed overhead of manufacturing even though it can have a significant contribution.
Cleaning costs grow with vessel size and with every batch, and they show up across the plant:
Solvent purchase. Fresh solvent for every wash.
Recovery and disposal. Distillation capacity, or waste handling and incineration.
Energy. Heating the vessel to reflux and cooling it again for each clean.
Lost capacity. Hours of reactor time spent cleaning instead of producing.
Labour and quality. Operator time, plus sampling and analysis to confirm each clean.
Sustainability targets. Every litre of solvent saved cuts process mass intensity and the emissions that come with making and destroying solvent.
Our calculator puts a figure on the solvent volume and its cost. The other lines add to the saving, so the true return from switching to flow is likely to be higher still.
Work out the numbers for your process
Our free cleaning solvent calculator lets you build this into your own investment case. Enter your product concentration, residence time and campaign length, and it sizes an equivalent batch reactor and compares the cleaning solvent each option needs. You can set how often the batch reactor is cleaned, adjust the cleaning assumptions for both reactors, and add your solvent and disposal cost in your own currency.
The results show the total solvent, the saving and the solvent used per kg of product. You can export everything to Excel or CSV to share with colleagues.
Every assumption is visible and can be changed:
RTR cleaning is a CIP flush, by default four reactor volumes (400 L) per clean.
Batch cleaning defaults to two washes of 30% of the vessel volume per clean, based on a published survey of a pharmaceutical batch plant [1]
The batch reactor is sized to match the RTR's output over one batch cycle, rounded to the nearest standard vessel size.
The results are indicative. They don't include ancillary equipment such as transfer lines, condensers, filters or dryers, and your actual cleaning requirement will be set by your own cleaning validation.
Put cleaning into your business case
If you are weighing up an investment in flow, don't leave cleaning out of the numbers. Open the cleaning solvent calculator here, enter your own process conditions and download the results for your business case. It takes less than a minute.
Want to see how your chemistry performs in flow? Our flow testing service lets you trial your process on Coflore reactors before you commit. Contact us or email sales@amt.uk to talk it through.
References
[1] ALAN T. PERKA , CHRISTINE S. GRANT & MICHAEL R. OVERCASH (1993) WASTE MINIMIZATION IN BATCH VESSEL CLEANING, Chemical Engineering Communications, 119:1, 167-177, DOI: 10.1080/00986449308936114
[2] GEORGE VERGHESE (2003) AQUEOUS CLEANING AND SOLVENT SUBSTITUTION IN CHEMICAL SYNTHESIS API MANUFACTURING, Pharmaceutical Technology Europe, 15:11, https://www.pharmtech.com/view/aqueous-cleaning-and-solvent-substitution-chemical-synthesis-api-manufacturing (Checked November 2026)
[3] ROBERT PEELING (2021) KEEPING IT CLEAN, Scientific Update, https://www.scientificupdate.com/topical-tips/keeping-it-clean/ (Checked November 2026)